Sooner or later someone will point at a number in your emissions report and ask where it came from. It might be a customer's procurement team, your finance director, an auditor engaged by a lender, or your own successor next year. If the answer is "a spreadsheet tab that Sam built", the conversation gets long.
A figure is defensible when three things can be shown for it: the source record and the exact place in it, the factor used and which published edition it came from, and the arithmetic that joins them. This post shows how ESGBlade keeps all three for every line, using the fictional demo company Cedarline Instruments.
The chain behind one tonne
1. The source: cited to the page
When you upload a utility or fuel bill as a PDF with a text layer, a deterministic reader pulls the quantity, unit, service period and account number into a draft activity line. The line keeps the page number and the quoted text it read. If a reviewer asks why San Jose's June gas line says 545 therm, the answer is the page and the words on it, not a recollection.
The extraction agent can explain what it read and flag where it is unsure, for example a service period that spans two months. It never changes a quantity. Scanned PDFs without a text layer are refused with a plain message, because there is nothing reliable to cite; those lines are entered by hand, with the source noted.
Lines also come from spreadsheet imports and from manual entry. Every line is a draft until someone confirms it, and an excluded line keeps its reason in the audit trail.
2. The factor: named, versioned, public
ESGBlade's factor library is built from published sources, each loaded as a named edition:
| Library | Edition | Factors | Used for |
|---|---|---|---|
| US EPA GHG Emission Factors Hub | 2025 | 417 | Fuels, refrigerants, travel, freight, waste in the US |
| US EPA eGRID | eGRID2023 | By subregion | Location-based US grid electricity |
| UK DESNZ conversion factors | 2026 | 2,248 | UK fuels, electricity, travel and more |
| US EPA USEEIO | 1.3 | 1,016 | Spend-based supply-chain factors by NAICS industry |

Because each result stores the factor key, library and edition, you can see which edition a figure used, which matters when you compare two years calculated with different editions.
Two conventions sit inside the factors and are worth knowing:
- Global warming potentials are IPCC AR5 100-year. Methane, nitrous oxide and refrigerants are converted to CO2e with AR5 values.
- Spend is adjusted to the factors' price year. USEEIO 1.3 factors are in 2022 US dollars. A spend line is converted to USD with the exchange rate on the line, then adjusted to 2022 dollars with CPI-U, before the factor is applied. Without that step, inflation alone would raise your Scope 3 each year.
Your own factor needs a source
You can add a custom factor, for example one from a supplier or an industry body. ESGBlade asks for its source, and that source travels with every result that uses it. A factor with no provenance can't be added.
When a line can't be calculated because nothing matches it, the factor matcher proposes a factor from the library, with its reason. A person accepts or rejects it. A factor that someone confirms for a kind of line is learned and offered the next time a similar line appears.
3. The arithmetic: the trace
Every result stores the calculation step by step. Open any activity line and the drawer shows it. Here is one of Cedarline's refrigerant lines at the Austin plant:

- Quantity as entered: 14 lb of R-404A added during service.
- Unit conversion: 14 lb is 6.3503 kg.
- Factor: the GWP of R-404A, 3,943, from the EPA Hub 2025 using IPCC AR5.
- Result: 6.3503 kg × 3,943 = 25,039 kg CO2e, about 25.0 t.
That arithmetic is ordinary deterministic code. AI in ESGBlade reads documents, drafts text and prepares work, but no model does the emissions sums. The same inputs give the same answer every time.
Following a number from the top
A reviewer usually starts at a total, not a line. The path down is short:
- On the inventory page, open the By category table. Each row, such as refrigerants at 58.2 t, has a How it's made link.
- That opens every line behind the row, with its factor and each step of the calculation.
- Open a line to see its trace and factor.
- If it came from a bill, follow the citation to the page and the quoted text.

The copilot side panel can do the same walk on request. Ask it to explain a figure and it reads the calculation trace with read-only tools; it can't edit anything. Disclosure items drafted from the inventory are checked against it, so a datapoint such as gross Scope 1 of 598.9 t points to the same numbers. More on that is on frameworks.
Who changed what
Traceability also means knowing who touched a line. Every change, by a person or by an agent, goes into the audit trail. Agents appear as themselves, with their agent code and autonomy level, so you can tell a confirmation Maya Chen made from a proposal the factor matcher prepared. When the period is signed, it is locked on the decision record until it is reopened. See security for how the audit trail is kept.
Where people stay in charge
- A person confirms every line. Lines start as drafts; a person confirms each one, or excludes it with a reason that stays in the audit trail.
- A person accepts each factor. The factor matcher proposes a factor with its reason; a person accepts or rejects it.
- Custom factors carry their source. The person adding a factor gives its source, and that source travels with every result that uses it.
- Your assurance provider gives assurance. The trace makes their review straightforward: every figure leads back to its page and its factor.
For the wider picture of building the inventory itself, start with Scope 1, 2 and 3 from the bills you already have.
A number you can defend has a page, a factor edition and the sum in between.
Try it on your own data
ESGBlade is free. Tell us about your company and we'll set up a workspace for your first reporting period.
Request a demo